Intended use

The FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 is an in vitro diagnostic test, based on real-time PCR technology, for the qualitative detection and differentiation of influenza A virus, influenza B virus and respiratory syncytial virus (RSV) specific RNA in human nasal and nasopharyngeal swab specimens collected in transport medium.

 

The FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 is intended to be used as an aid for diagnosis of influenza A virus, influenza B virus and RSV infection.

 

The results generated with the FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 have to be interpreted in conjunction with other clinical and laboratory findings.

 

The FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 is intended for use by professional users trained in molecular biological techniques and in vitro diagnostic procedures.

 

Specifications

Key features

  • Detection and differentiation of influenza A virus, influenza B virus and respiratory syncytial virus (RSV) specific RNA
  • Parallel detection of all pathogens in a single reaction
  • Includes No Template Control (NTC) and Positive Control (PC)
  • To be used with the FlexStar® (RT-)PCR Amplification Mix 1.5 and the AltoStar® Internal Control 1.5
  • CE-IVD marked* in vitro diagnostic test
  • Analytical sensitivity reported in copies/ml
 

Limit of detection (LoD)

  • LoD influenza A virus nasal and nasopharyngeal swab specimens in transport medium: 978 copies/ml
  • LoD influenza B virus nasal and nasopharyngeal swab specimens in transport medium: 652 copies/ml
  • LoD RSV nasal and nasopharyngeal swab specimens in transport medium: 666 copies/ml

 

Sample types

The following sample types are validated for use with the FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5:
 
Human nasal and nasopharyngeal swab specimens collected in transport medium

 

For use with

The FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 can be used with compatible workflows (manual or automated). Real-time PCR instruments that have been validated for use with the FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 are:

CFX96™ Deep Well Dx System (Bio-Rad)

CFX96™ Dx System (Bio-Rad)

QuantStudio™ 5 Real-Time PCR System (Applied Biosystems)

Rotor-Gene® Q5/6 plex Platform (QIAGEN)

 

* according to Regulation (EU) 2017/746 (IVDR).

Order No
FS0061543
Rxns
96
Transportation
Dry ice
Regulatory status
CE-IVD

Products not licensed with Health Canada and not FDA cleared or approved. Products not available in all countries.

Manuals FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5
Associated documents FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5
Contact sales

Find your responsible sales representative.

Contact order processing

Order reagents, kits, instruments and implementation equipment for your workflow and laboratory routine.

Manuals FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5
Language
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - EN
Language: English
Date: 2026-06
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - DE
Language: German
Date: 2026-06
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - ES
Language: Spanish
Date: 2026-06
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - FR
Language: French
Date: 2026-06
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - IT
Language: Italian
Date: 2026-06
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - PL
Language: Polish
Date: 2026-06
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - PT
Language: Portuguese
Date: 2026-06
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - RO
Language: Romanian
Date: 2026-06
Panel: Respiratory infections
Regulatory status: CE-IVD
Associated documents FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5
Language
Type of document
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - EN - DoC
Language: English
Date: 2026-09-16
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - DE - DoC
Language: German
Date: 2026-09-16
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - ES - DoC
Language: Spanish
Date: 2026-09-16
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - FR - DoC
Language: French
Date: 2026-09-16
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - IT - DoC
Language: Italian
Date: 2026-09-16
Panel: Respiratory infections
Regulatory status: CE-IVD
FlexStar® FLU Type & RSV RT-PCR Detection Mix 1.5 - PT - DoC
Language: Portuguese
Date: 2026-09-16
Panel: Respiratory infections
Regulatory status: CE-IVD